The top burners are working but the oven won't. Please enter a valid email address. F5 - Control Board Failure - Replace control board (clock). FdU Door unlock error A Door Unlock Error occurs if the door cannot be unlocked. his comment is here

Up next Whirlpool Oven Error Codes - Duration: 3:12. Check the jumpers in the harness to make sure they agree with the actual oven size. If corrections are made in any step, reconnect power to control. Disconnect power and unplug the unit to check wire harness connections to the motor, MCU, and Central Control Unit (CCU).

Whirlpool Super Capacity 465 Error Codes E1 F5

Check the door switch/lock for any debris or foreign objects. Allow at least a minute after power has been restored and if error code reappears, replace control board (clock). Credentials confirmed by a Fortune 500 verification firm. About Press Copyright Creators Advertise Developers +YouTube Terms Privacy Policy & Safety Send feedback Try something new!

Press PAUSE/CANCEL twice to clear the display. Press and HOLD start to continue the cycle, or press 'Stop/Cancel' to clear display and cancel cycle. Fault Codes Fault Codes Admiral Bosch Dacor Estate Frigidaire GE Gibson Hotpoint Jenn Air Kelvinator Kitchen Aid Magic Chef Maytag Roper Sears / Kenmore Tappan Thermador Whirlpool We are Safe, Secure, E1 F5 Error Code Whirlpool Oven The system returned: (22) Invalid argument The remote host or network may be down.

A&E factory service does most brands warranty services. Whirlpool Super Capacity 465 Manual Press and hold any key for 1 minute to clear R failure code from memory. Potential Causes • If too much detergent was used, run the unit through a Rinse/ Spin cycle then a Normal cycle without adding any detergent. http://www.appliancepartspros.com/repair-help/whirlpool-fault-codes.html Reply With Quote December 17th, 2007,12:22 PM #8 Jake View Profile View Forum Posts Visit Homepage Appliance Tech - Admin Join Date Aug 2004 Location McMullen Valley, Arizona Posts 79,885 Glad

Press and hold any key for 1 minute until F2 E0 code is displayed. 3. Whirlpool Super Capacity 465 Error Code Pf F5 - E0 Door switches do not agree (condition exists when door switch is closed indicating an open door, and latch switch is closed indicating a locked door) 1. Skip to content Sign In Join or Activate Products Departments Departments Shop Shop Explore Explore Advice Advice Rewards Rewards More More Home / Brands / Manage My Life / Questions F1-E3 - Wiring Harness Cavity Size Does Not Match Stored Value - Check the jumpers in the harness to make sure they agree with the actual oven size.

Whirlpool Super Capacity 465 Manual

If there is an error reading this data it will cause this error. When this error occurs, the pump should be cycled in drain mode for 30 seconds on and 30 seconds off until the switch resets. Whirlpool Super Capacity 465 Error Codes E1 F5 The machine control board may have a bad relay and may need to be replaced. Whirlpool Oven Error Code F5e1 Error code - E1 - F5.

LF - Long Fill - If the water fill time exceeds ten minutes, the water valves will be shut off and this error code will display. this content Whirpool Duet Front Loading Automatic Washer Fault Codes FH - Detects No Water Entering Machine or No Pressure Switch Trip - Select 'cancel' twice to clear this code. Look for welded relay contacts on bake or broil relays. Sr - Stuck Relay - The machine control board may have a bad relay and may need to be replaced. Whirlpool Super Capacity 465 Error Codes E2 F3

  • Potential Causes • Check Wire Harness connections to the MCU, the motor, and Central Control Unit (CCU) • Check Drive belt • Check MCU • Check Motor • Check Wire Harness
  • Appliance Princess 3,176 views 3:03 Loading more suggestions...
  • Press CANCEL and observe for 1 minute to ensure operation is correct. 6.
  • When started E1 -F5- appears on screen.
  • Observe to see if door locks.
  • ApplianceVideo.com 700 views 1:27 How to Fix an F1 Error On a Kenmore or GE Range - Duration: 11:41.

F2 Oven temperature is too high 1. Look for condensation or contamination on probe receptacle. If the door is not locking, then 1 minute from the start of clean, the F5 E1 code will again be displayed. weblink CA / CI - Average Current Limit / Instantaneous Current Limit - This error code may signify a problem with the drive motor, thermal protector, or motor controller.

Verify CCU is working by performing diagnostic test or any cycle. Whirlpool Accubake Oven Error Codes E1 F5 Sometimes these work, but if the control has failed it won't make any difference.Thanks for using FixYa - a 4 THUMBS rating is appreciated for answering your FREE question.%#FDG Jan 02, Ste. 500, Encino, CA 91436 1-877-477-7278 Tennessee 240 Edwards St.

If damage is found, replace appropriate part.

F2 - Oven Temperature Is Too High - Check for welded contacts on bake and broil relays. Bill Newberry 17,190 views 3:36 Who Locked the Stove (12/8/10 - DAY 276-277) - Duration: 5:55. F6-E0 - Return Line Not Connected - This error should appear within 60 seconds after power up to appliance. Whirlpool Super Capacity 465 Gas Range Ignitor If no damage to wires and all connectors okay, proceed to step C.

If error code reappears then replace the touch pad, or touch pad and control board (clock) if all one assembly. Check MCU by looking for operations of the drive motor and check drive motor for powered rotations. Chat Conversation StartedTim Alan : hi my name is XXXXX XXXXX I can help you with thisJACUSTOMER-o5ui89dk- : OK. check over here Earned 7,028 community points in Click'>Whirlpool March 1st, 2012 Answered in 22 hours Comment 0 votes Didn't find what you are looking for?

Neil PS. Press 'Stop/Cancel' to clear display. Electronic Range Control, ERC, Electronic Oven Control, EOC, control board, and clock all refer to the same part. 4 Digit Fault Codes F1-E0 - EEPROM Communication Error - Disconnect power for Check CCU is also operational by performing a diagnostic test or any cycle.

Random Repair 66,386 views 9:38 Fixing an Oven that got Stuck with the Door Locked After Self-Clean - Duration: 10:49. I had so many questions and they answered them all." Sharon S. Appliance Repair Forums Dec 30, 2014 | Whirlpool Kitchen Ranges 1 Answer I have a whirlpool gold self-cleaning, accubake system, super capacity 465. All F3-E Codes - Oven Temperature Sensor (RTD) or Warming Drawer Defect - Replace oven temperature sensor (RTD).