How To Repair Winsock 2.0 Error (Solved)


Home > Socket Error > Winsock 2.0 Error

Winsock 2.0 Error

Contents

WSAENOTCONN 10057 Socket is not connected. On a datastream socket, the connection was reset. WSAEDESTADDRREQ 10039 Destination address required. WinSock functions: gethostbyaddr(), gethostbyname(), WSAAsyncGetHostByAddr(), WSAAsyncGetHostByName(), WSAAsyncGetProtoByName(), WSAAsyncGetProtoByNumber(), WSAAsyncGetServByName(), WSAAsyncGetServByPort() Additional functions: It is strange that the asynchronous protocol and services functions can fail with this error, but the synchronous cannot. http://nbxcorp.com/socket-error/winsock-2-error.html

No part of this website should be reproduced or redistributed in any form without the author's written permission. Berkeley description: Only one usage of each address is normally permitted. Note that this error is returned by the operating system, so the error number may change in future releases of Windows. The socket is marked as non-blocking (non-blocking operation mode), and the requested operation is not complete at this time. https://msdn.microsoft.com/en-us/library/windows/desktop/ms740668(v=vs.85).aspx

Socket Error 10054

WinSock functions: With a datastream socket: connect() and FD_CONNECT WSAAsyncelect() notification message. recv(), recvfrom(), send(), sendto(): MSG_OOB was specified, but the socket is not of type SOCK_STREAM Developer suggestions: don't do that. This error may also be returned for protocol and service queries, and means that the specified name could not be found in the relevant database.

According to AT&T repair center the latest firmware is installed on both modems (original and spare) as of Sep 2010 when I took the original modem in and purchased the spare. WSANO_DATA 11004 Valid name, no data record of requested type. Technology[edit] The Windows Sockets API specification defines two interfaces: the API used by application developers, and the SPI, which provides a means for network software developers to add new protocol modules Socket Error 10049 WinSock only allows a single blocking operation to be outstanding per task (or thread), and if you make any other function call (whether or not it references that or any other

Uninstall and Reinstall NetZero The following instructions will help guide you through this process. Winsock Error Windows 7 The most significant change was the inclusion of the gethostname() function. WSAEREMOTE 10071 Item is remote. https://support.microsoft.com/en-us/kb/811259 press enter Also, can you update the firmware on AT&T's Modem?

WinSock description: Same as Berkeley. Socket Error 10054 Connection Reset By Peer No more file handles are available, so no more files can be opened. WinSock description: Same as Berkeley. Can indicate a service provider implementation error.

  • This normally results from a loss of the connection on the remote socket due to a timeout or a reboot.
  • WinSock functions: socket() See also: WSAESOCKTNOSUPPORT WSAEPROTOTYPE (10041) Protocol wrong type for socket.
  • This won't reveal too much unless you know the router addresses at the remote end, but it might help to identify if the problem is somewhere along the way.
  • Bonjour? @Bill - Thanks for the info, Bill.
  • Sometimes a reboot will fix this, other times, we are forced to reset the winsock.
  • At least one QoS reserve has arrived.
  • An object with an invalid ObjectLength field was specified in the QoS provider-specific buffer.
  • It was also the first version to remove support for 16-bit Windows applications.
  • To check which LSPs are installed, use netsh winsock show catalog command. 2) For your connectivity problems, I think you need to explore alternate drivers.

Winsock Error Windows 7

WSAENETRESET (10052) Network dropped connection on reset. WinSock functions: accept(), bind(), closesocket(), connect(), gethostbyaddr(), gethostbyname(), gethostname(), getpeername(), getprotobyname(), getprotobynumber(), getservbyname(), getservbyport(), getsockname(), getsockopt(), ioctlsocket(), listen(), recv(), recvfrom(), select(), send(), sendto(), setsockopt(), shutdown(), socket(), WSAAsyncGetHostByAddr(), WSAAsyncGetHostByName(), WSAAsyncGetProtoByName(), WSAAsyncGetProtoByNumber(), WSAAsyncGetServByName(), Socket Error 10054 WinSock functions: See also: WSAECONNABORTED, WSAECONNRESET, WSAENETRESET, WSAETIMEDOUT WSAEHOSTUNREACH (10065) No route to host. Winsock Error 10053 No process may have more than a system-defined number of file descriptors open at a time.

One is not connected Internet Speed DSL Antivirus Avira Internet Security Browser IE 11 Other Info ATI HDMI Audio Jacee View Public Profile Find More Posts by Jacee 12 Nov 2010 Check This Out This is what occurs in Berkeley Sockets. A name component or a name was too long. User suggestions: Chances are the network subsystem is misconfigured or inactive. What Is A Socket Error

This error is also returned if the service provider returned a version number other than 2.0. Developer suggestions: Handle this as a non-fatal error. Berkeley description: A request to send data was disallowed because the socket had already been shut down with a previous shutdown() call. http://nbxcorp.com/socket-error/winsock-error-997.html WSAEMSGSIZE 10040 Message too long.

In some instances, it also refers to the current state of the socket input parameter. Winsock Error 10061 It can occur if you're trying to run too many applications (of any kind) simultaneously on your machine. NGCV Appendix C: Error Reference [Go to Top] Detailed Error Descriptions Errorless Functions Functionless Errors Error Description List The Windows Sockets specification describes error definitions for each function, but it does

All sockets are created with an associated address family (that is, AF_INET for Internet Protocols) and a generic protocol type (that is, SOCK_STREAM).

Developer suggestions: Things an application developer can do to avoid the error. The error can occur when the local network system aborts a connection. Alternately, you can get the local IP address by calling gethostname() followed by gethostbyname(). Socket Error Codes Linux Winsock LSPs are available for a wide range of useful purposes, including Internet parental controls, web content filtering, QoS etc.

If you are using a host table exclusively, you'll need to update it to add the destination hostname and address. Berkeley description: An operation was attempted on something that is not a socket. WinSock functions: accept(), bind(), closesocket(), connect(), gethostbyaddr(), gethostbyname(), gethostname(), getpeername(), getprotobyname(), getprotobynumber(), getservbyname(), getservbyport(), getsockname(), getsockopt(), ioctlsocket(), listen(), recv(), recvfrom(), select(), send(), sendto(), setsockopt(), shutdown(), socket(), WSAAsyncGetHostByAddr(), WSAAsyncGetHostByName(), WSAAsyncGetProtoByName(), WSAAsyncGetProtoByNumber(), WSAAsyncGetServByName(), http://nbxcorp.com/socket-error/winsock-ftp-error.html WinSock description: Same as Berkeley.

netsh int ip reset reset.log hit (reset TCP/IP stack) http://support.dell.com/support/down...nConsent=False Read more: http://windows7themes.net/repair-reset-winsock-windows-7.html#ixzz15B58tLUR My System Specs Computer type PC/Desktop System Manufacturer/Model Number Home built OS Windows 7 Ult, Windows 8.1 Pro, If so, is there an older DLL in a directory in the path ahead of the directory containing the newer DLL? For example, the ARPA Internet UDP protocol cannot be specified with a socket type of SOCK_STREAM. WSAENOBUFS 10055 No buffer space available.

WinSock functions: listen(), FD_CONNECT Additional functions: connect(), sendto() WSAELOOP (10062) Too many levels of symbolic links. Click on both files and continue This will add Winsock and Winsock 2 to your registry again but may not have the correct information inside which is why we need I double-checked Dell support for any updated drivers and I have the latest installed. @jacee - Your comment about a program trying to connect to the Internet got me thinking. The API guarantees that a conforming application will function correctly with a conforming protocol implementation from any network software vendor.

We took the text of the errno manual page in BSD 4.3, filled in gaps and embellished, completing the information. This is not a soft error, another type of name server request may be successful. An invalid QoS provider-specific buffer. WinSock functions: Any function which allocates a new descriptor: accept(), listen(), & socket().

WSAEHOSTUNREACH 10065 No route to host. No more results can be returned by the WSALookupServiceNext function. Note that this error is returned by the operating system, so the error number may change in future releases of Windows. Berkeley description: The host you were connected to crashed and rebooted.

An example is using a broadcast address for sendto without broadcast permission being set using setsockopt(SO_BROADCAST). So all previously-installed LSPs must be reinstalled. For protocols and services resolution, it means the respective database wasn't located. See also: WSAECONNABORTED, WSAECONNRESET, WSAENETRESET WSAETOOMANYREFS (10059) Too many references; can't splice Berkeley description: too many references to some kernel-level object; the associated resource has run out.

It's also possible that the local services file has an incorrect port number (although it's unlikely). If so, then the application might have had a problem resolving the name (see suggestions at WSATRY_AGAIN for more information).