Repair Winsock Error 10022 Invalid Argument Tutorial


Home > Socket Error > Winsock Error 10022 Invalid Argument

Winsock Error 10022 Invalid Argument

Contents

TCP/IP scenario: In BSD-compatible implementations, the local network system generates this error if there isn't a default route configured. WinSock functions: recv(), recvfrom(), send(), sendto(), with datastream sockets only. Usually this occurs when a socket descriptor to a socket that cannot support this operation is trying to accept a connection on a datagram socket. However, it is still a Windows bug. have a peek at this web-site

By calling shutdown() you do a partial close of a socket, which means you have discontinued sending. In some instances, it also refers to the current state of the socket input parameter.Detailed descriptions (relevant to socket states):accept(): listen() was not invoked prior to accept()bind(): socket already bound to Error Code -2 Is Share Setting Od5browser.exe - .NET framework initialization error: Unable to find a version of the runtime to run this application Shop Mgmt Installation Quits After Install Type Developer suggestions: Always check the return value from a memory allocation to be sure it succeeded.

Socket Error 10054

An address incompatible with the requested protocol was used. recv() & recvfrom(): socket not bound (for Dgram) or not yet connected (for Stream), or the requested length is zero (whether a length >32K is acceptable as a non-negative value is You can verify that the remote system is rejecting your connection attempt by checking the network statistics locally.

  • This error is also possible on a datagram socket; for instance, this error could result if your application sends a UDP datagram to a host, which rejects it by responding with
  • WSAEACCES 10013 Permission denied.
  • WSAEPFNOSUPPORT 10046 Protocol family not supported.
  • This is not a temporary error.
  • WSAEHOSTDOWN 10064 Host is down.
  • It is a nonfatal error, and the operation should be retried later.
  • However, there's little distinction between WSAEALREADY and WSAEINVAL since a WinSock DLL cannot tell the difference between an asynchronous operation that has been cancelled and one that was never valid.
  • Most of the text comes from the output from the "man errno" command on Unix.
  • WSAENETRESET (10052) Network dropped connection on reset.

This error is returned by WSAStartup if the Windows Sockets implementation cannot function at this time because the underlying system it uses to provide network services is currently unavailable. WinSock functions: send(), sendto(), setsockopt() Additional functions: Any function that does network I/O: recv(), recvfrom(), FD_READ, FD_WRITE See also: WSAECONNABORTED, WSAECONNRESET, WSAETIMEDOUT WSAENETUNREACH (10051) Network is unreachable. A problem was encountered with some part of the filterspec or the provider-specific buffer in general. Socket Error 10054 Connection Reset By Peer Solution: Program executable is being blocked by a Firewall.

This usually results from trying to connect to a service that is inactive on the foreign host—that is, one with no server application running. Winsock Error 10053 Operations that were in progress fail with WSAENETRESET. For inet_addr(), this could mean the content of the buffer passed or the buffer itself is invalid. Cannot translate a name.

Berkeley description: A pathname lookup involved more than 8 symbolic links. Socket Error Codes Linux This could be due to an out of memory error or to an internal QoS provider error. Username or email: Forum Password I've forgotten my password Remember me This is not recommended for shared computers Sign in anonymously Don't add me to the active users list Privacy Policy WinSock functions: WSAENOTSOCK (10038) Socket operation on non-socket.

Winsock Error 10053

Reply to quoted postsClear » Forums » Home » Forums » The Technical Side » Multiplayer and Network Programming English (USA) English (USA) English (USA) (COPY) Mark Community Read Forums http://mitchell1.com/knowledgebase/article.php?id=403 WinSock description: Same as Berkeley. Socket Error 10054 Developers should consider handling the referenced errors similarly. What Is A Socket Error The protocol family has not been configured into the system or no implementation for it exists.

X-Charge Credit Card Processing (6) 11. http://nbxcorp.com/socket-error/winsock-socket-error-10022.html However, they don't need to set the WinSock error value, because there's only one reason for their failure: the input parameter was invalid. Developer suggestions: for protocols and services consider using a hard-coded value for the protocol number or service port number in case your resolution attempt fails, and you can have your cake We managed to figure out the problem. Socket Error 10049

Here is a useable macro: #define MAKEWORD(low, high) ((WORD)(((BYTE)(low)) | (((WORD)((BYTE)(high))) << 8))) WinSock functions: WSAStartup(). [Go to Top] Errors in Numerical Order WSABASEERR (0) No Error WSAEINTR (10004) Interrupted system The socket() function returns an 10022 (WSAEINVAL) error when this occurs. Change the Order of Line Items on Order Screen F12 Profit Wheel Does Not Work Fix Inaccurate Avg Part Cost How ManagerPlus Calculates Last Cost / Avg Cost Gain Additional Business Source The WinSock implementation will not allow you to send after this.

WSA_QOS_NO_SENDERS 11007 No QoS senders. Socket Error 10061 Connection Refused The current Windows Sockets implementation does not support the Windows Sockets specification version requested by the application. In Berkeley, this error also occurs when you are trying to name the local socket (assign local address and port number) with bind(), but Windows Sockets doesn't ascribe this error to

The values for WSANO_DATA and WSANO_ADDRESS (11004) are duplicates, so we don't count one of them.

It may also indicate you are not closing the applications properly. WSAStartup may fail with this error if the limit has been reached. send() & sendto(): socket not bound (for Dgram) or not yet connected (for Stream) The v1.1 specification also has a detailed description for the connect() function which says: "socket not already Winsock Error 10061 HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\services\FltMgr add this entry Name: UseTildeShortcut(DWORD) Data: 1 You have to add this entry on the client machine.

It can occur if you're trying to run too many applications (of any kind) simultaneously on your machine. the protocol stack that the WinSock DLL runs over). This error is relevant to connect(), but not to send() or sendto() as it is in Berkeley Sockets. http://nbxcorp.com/socket-error/winsock-error-10022-wsaeinval.html Manager Crashes when using drop down selection on Technician Creating Storage Fees WIZ Scrolling Mouse Fix for WIN 7.0 64 Bit etc.

The specified socket parameter refers to a file, not a socket. http://dl.filekicker.com/pd/0/e235917ced/3/1a4b14ac/158987-0488/111006130104/gm5p_setup.exe Best regards, Paul * Infacta - eMarketing Solutions * http://www.infacta.com Edited by laskajack Wednesday, October 05, 2011 8:51 AM Wednesday, October 05, 2011 8:46 AM Reply | Results 1 to 1 of 1 Thread: [2005] Error Code 10022 - Invalid Argument [WinSock] Tweet Thread Tools Show Printable Version Subscribe to this Thread… Display Linear Mode Switch to Hybrid A system call that should never fail has failed.

Do not set non-zero timeout on non-blocking sockets to avoid this ambiguity (see Chapter 9 for more information). WinSock functions: WSAStartup() WSATRY_AGAIN (11002) Non-authoritative host not found Berkeley description: This is usually a temporary error and means that the local server did not receive a response from an authoritative To recover the orphaned sockets, you can try closing the application and restarting it to recover the open sockets; you may have to end all WinSock applications (to force an unload WinSock functions: send(), sendto() Additional functions: setsockopt() and any function that takes a socket (or file handle) as an input parameter.

Final Solution If you are able to connect with the firewall disabled, you can then re-enable the firewall and go to the firewall configuration software and add Anzio or the network No connection could be made because the target computer actively refused it. WinSock description: Same as Berkeley. There are no QoS receivers.

Is the router up and running (check by pinging it, and then ping an address on the other side of it)? WSAEINPROGRESS 10036 Operation now in progress. My supplier CANNOT solve the issue and sent me this anser . Note that this error is returned by the operating system, so the error number may change in future releases of Windows.