Repair Winsock Error Wsaetimedout Tutorial


Home > Socket Error > Winsock Error Wsaetimedout

Winsock Error Wsaetimedout

Contents

copies what it can into your buffer) and fails the function. See also: WSAECONNABORTED, WSAENETRESET, WSAETIMEDOUT WSAEDESTADDRREQ (10039) Destination address required. Often when someone is connected through VPN; you may see this error because your local and remote ip addresses overlap. The WinSock API does not provide any way to select specific name resolution protocols, server address, or record type. have a peek at this web-site

Although some WinSock implementations might not issue other errors if a connection fails, so you can handle this error as you would others that indicate connection failure. The file handle supplied is not valid. WSATRY_AGAIN 11002 Nonauthoritative host not found. An application used a Windows Sockets function that directly maps to a Windows function. https://msdn.microsoft.com/en-us/library/windows/desktop/ms740668(v=vs.85).aspx

Socket Error 10054

Developer suggestion: are you trying to use an optional feature? WSAEMSGSIZE (10040) Message too long. Check your WinSock implementation documentation to be sure all necessary components are currently installed and configured correctly. Winsock functions: bind(), connect(), listen(), FD_CONNECT WSAEADDRNOTAVAIL (10049) Cannot assign requested address.

  1. A call to the WSALookupServiceEnd function was made while this call was still processing.
  2. WSAEOPNOTSUPP 10045 Operation not supported.
  3. But from what I'm told, filtering between VLANs does not work this way (the same way that firewalls do), and it's more like an application-layer firewall where you must define specific
  4. The error can also occur in an attempt to rename a file or directory or to remove an existing directory.

more hot questions question feed about us tour help blog chat data legal privacy policy work here advertising info mobile contact us feedback Technology Life / Arts Culture / Recreation Science WSAEPROTOTYPE 10041 Protocol wrong type for socket. In some instances, it also refers to the current state of the socket input parameter. Socket Error 10049 Berkeley description: An asynchronous signal (such as SIGINTor SIGQUIT) was caught by the process during the execution of an interruptible function.

Among other things, that is exactly what we've done here. For instance, this error will occur if you try to run two applications that have FTP servers. WSASYSNOTREADY 10091 Network subsystem is unavailable. anchor WSAEPROVIDERFAILEDINIT 10106 Service provider failed to initialize.

Other information varies between different errors. Socket Error 10054 Connection Reset By Peer recv(m_socket, pszBuffer, m_nSize, 0);... more stack exchange communities company blog Stack Exchange Inbox Reputation and Badges sign up log in tour help Tour Start here for a quick overview of the site Help Center Detailed WSA_QOS_SENDERS 11006 QoS senders.

Socket Error 10053

Specifically, the v1.1 Windows Sockets specification notes the domain name system (DNS) errors "FORMERR, REFUSED, and & NOTIMP. http://support.dameware.com/kb/article.aspx?ID=300060 Notice that asynchronous service and protocols functions are listed below, in addition to the hostname resolution functions. Socket Error 10054 A firm farewell - Rest in piece English fellow vs Arabic fellah What would be the value of gold and jewelry in a post-apocalyptic society? Socket Error Codes Linux The application has initiated an overlapped operation that cannot be completed immediately.

An invalid QoS provider-specific buffer. http://nbxcorp.com/socket-error/winsock-2-error.html The only function that takes these two explicit parameters is socket(). Specifically, these error-less functions are the byte order functions ( htonl(), htons(), ntohl(), and ntohs()), the address manipulation functions (inet_addr(), and inet_ntoa), WSAGetLastError() and WSAIsBlocking(). By default, it's currently set to Socket Logon Timeout=90000 (in milliseconds), so you can try doubling that value to start out. Winsock Error 10061

Return code/valueDescription WSA_INVALID_HANDLE 6 Specified event object handle is invalid. WinSock functions: accept(), bind(), closesocket(), connect(), gethostbyaddr(), gethostbyname(), gethostname(), getpeername(), getprotobyname(), getprotobynumber(), getservbyname(), getservbyport(), getsockname(), getsockopt(), ioctlsocket(), listen(), recv(), recvfrom(), select(), send(), sendto(), setsockopt(), shutdown(), socket(), WSAAsyncGetHostByAddr(), WSAAsyncGetHostByName(), WSAAsyncGetProtoByName(), WSAAsyncGetProtoByNumber(), WSAAsyncGetServByName(), WSAEMSGSIZE 10040 Message too long. http://nbxcorp.com/socket-error/winsock-ftp-error.html It may also make explicit mention of other functions that can fail with this error.

Does using NetDrive on my home network take the "long road" back to my external drive, meaning, does my data go out of my home network only to come back through Socket Error 10061 Connection Refused WSAECONNRESET (10054) Connection reset by peer. Microsoft C description: Too many open files.

WSANO_DATA 11004 Valid name, no data record of requested type.

share|improve this answer answered Sep 18 '15 at 21:13 Remy Lebeau 234k13144273 Maybe I have the wrong idea on how a socket works, but since udp does not guarantee Developer suggestions: for protocols and services consider using a hard-coded value for the protocol number or service port number in case your resolution attempt fails, and you can have your cake An invalid policy object was found in the QoS provider-specific buffer. Winsock Error 10060 If you used a hostname, did it resolve to the correct address?

WSA_IO_INCOMPLETE 996 Overlapped I/O event object not in signaled state. Typically, only one usage of each socket address (protocol/IP address/port) is permitted. For example, the error can occur when an attempt is made to read from a file that is not open, to open an existing read-only file for writing, or to open http://nbxcorp.com/socket-error/winsock-error-997.html The most common cause is an incorrectly configured server, full server, or incorrect Port specified by the client.

WSAEADDRINUSE 10048 Address already in use. The requested service provider is invalid. The specified file handle is not a valid file-handle value or does not refer to an open file; or an attempt was made to write to a file or device opened WinSock description: Almost same as Berkeley.

Securing a LAN that has multiple exposed external Cat 6 cable runs? But make note this does not open the ports required to remotely install, remove, start, or stop the MRC Client Agent Service, only the port specified to use for communication. In this case, the 2nd application will fail with WSAEADDRINUSE. Detailed descriptions: connect(): the operation is underway, but as yet incomplete.

Cannot translate a name. User suggestions: Check that you have a name server(s) and/or host table configured. You get a WSAECONNABORTED when the remote end of the connection, or possibly an intermediary router, resets the connection and sends an RST. The v1.1 WinSock specification doesn't list any errors for these functions.

Berkeley description: An operation was attempted on something that is not a socket. User suggestions: see WSAHOST_NOT_FOUND for details. But most of these function-less errors are simply out of place; they are inappropriate to the Windows Sockets API as it exists in the v1.1 specification.