This is because the root device now has a different name (for example, it might have been changed to /dev/hda1). The Converter Standalone SDK is a ZIP file that contains the following items. If some changes occur on the source machine (such as adding memory or hard drives) after this information is retrieved, the Conversion wizard does not show information about the changes. Re: 98% FAILED: Unable to reconfigure the destination virtual machine. Check This Out

BSOD), the errors in the log are:2013-07-01T16:56:00.460-04:00 [03188 error 'task-3'] Error 2 (opening key) saving registry key mntApi163093493130307997\ControlSet001\Services\rhelfltr into \\.\vstor2-mntapi20-shared-6E126F12000010000000000005000000\WINDOWS\$Reconfig$\mntApi163093493130307997-ControlSet001-Services-rhelfltr-reg2013-07-01T16:56:00.507-04:00 [03188 error 'task-3'] Error 2 (opening key) saving registry key mntApi163093493130307997\ControlSet001\Services\rhelnet NOTconfigureVMinP2V.jpg 0 LVL 117 Overall: Level 117 VMware 109 Windows Server 2003 18 Message Active today Expert Comment by:Andrew Hancock (VMware vExpert / EE MVE)2014-10-07 I'll check the log for Thanks. 0 LVL 117 Overall: Level 117 VMware 109 Windows Server 2003 18 Message Active today Expert Comment by:Andrew Hancock (VMware vExpert / EE MVE)2014-10-21 Don't feel guilty, all questions Just mount it to a drive letter and copy the file. - remove the vmdk from the VM without deleting it from disk!HTHPlamen Like Show 0 Likes (0) Actions 4. https://communities.vmware.com/thread/450992?start=0&tstart=0

Vmware Converter Failed At 98 Unable To Find The System Volume

Virtual machines cloned from SLES 11 SP1 sources to ESX/ESXi managed destinations boot in console mode After the conversion, the destination virtual machine cannot load the GNOME Display Manager and boots Microsoft Windows Vista or later is installed as a second operating system on the source physical machine and later is removed, but the BCD manager is left on the source machine. Therefore, you cannot use previous Converter versions to convert sources that have already been converted with Converter Standalone 5.5.

  • Login.
  • Should work find now. (3:00 AM) So, this process is way easier if you just re-do the conversion.
  • Solution for this kind scenario: If you are converting physical machine to virtual, there are couple of things needs to check 1: Before converting a physical machine to virtual ,you should
  • During conversion or configuration, if you choose to customize Microsoft Windows Vista and provide wrong customization information, for example an invalid serial key, the customized destination reboots repeatedly.
  • I have tried to convert CentOS 6.4 from P2V.
  • Workaround 1: Mark all non-boot active partitions on the destination machine as inactive and run configuration on the destination machine.
  • You cannot import a Windows source with "signature()" in the boot.ini file You cannot import a Window source with "signature()" in the boot.ini file.
  • Conversion jobs from and to ESX hosts that are not connected to vCenter Servers fail if the number of disks on the source machine is more than nine When converting a
  • Click Next to view a summary of the conversion job.

Join Now Hi, I was converting a Physical running server to virtual with the help of VMware Vcenter converter but at 98% it got failed,has anyone aware of this issue. HOW TO: P2V, V2V for FREE - VMware vCenter Converter Standalone 5.5 HOW TO: FAQ VMware P2V Troubleshooting 0 LVL 3 Overall: Level 3 Message Active 5 days ago Author Older versions of VMware products have limited support of newer operating systems. Bcdedit /deletevalue Increaseuserva The number of LVM logical volumes on a source LVM volume group cannot exceed 12.

Click Advanced and select the Destination layout tab. Vmware Converter Failed Unable To Create Reconfig Windows 7 Everybody is just happy it keeps running because it’s on 10 year old hardware. The number of LVM logical volumes per volume group is limited to 12 for powered on Linux sources During the conversion of powered on Linux machines, Converter Standalone converts LVM volume https://kb.vmware.com/kb/1034984 Enter inactive.

Enter inactive. Vstor2-mntapi20-shared So, there is the cause…so how do I fix it. Email Reset Password Cancel Need to recover your Spiceworks IT Desktop password? Win srvr 2003 a.p.

Vmware Converter Failed Unable To Create Reconfig Windows 7

You may get a better answer to your question by starting a new discussion. https://kb.vmware.com/kb/1006284 This conversion failed near the end. Vmware Converter Failed At 98 Unable To Find The System Volume You may get a better answer to your question by starting a new discussion. Error Cannot Open The Destination Virtual Machine For Reconfiguration The following warning message appears: GdmLocalIDisplayFactory: maximum number of X display failures reached: check X server log for errors.

The source virtual machine does not have the appropriate drivers The following error message appears in the log file when reconfiguration fails because the appropriate drivers are missing from the source http://nbxcorp.com/vmware-converter/vmware-converter-error-unable-to-clone-disk.html All images for the backup of a machine must be in a single folder that contains no other images (ShadowProtect and Backup Exec System Recovery). The following error message appears in the Job summary tab for the first conversion job: FAILED: A general system error occurred: No connection could be made because the target machine actively Workaround: Place each backup in its own folder before using Converter Standalone to convert an image. Vmware Converter Fails At 98 Windows 7

Join our community for more solutions or to ask questions. I followed instructions of Luciano Patrão (disabled non-Microsoft services, etc.) and Andrew Hancock (De-selected "Power on target machine" & de-selected "Install VMware Tools on the imported machine". Enter select disk . (Optional) To list the partitions on the selected disk, enter list partition. http://nbxcorp.com/vmware-converter/vmware-converter-error-unable-to-reconfigure-the-destination-virtual-machine.html Creating a conversion job to convert a standalone VMware source with a VMDK file greater than 2GB from a network share that does not support large files, fails If you select

Note: The timeout value is measured in milliseconds. Windows 7 Boot.ini Location Workaround 2: Mark all non-boot active partitions on the source machine as inactive and attempt to run the conversion again. When converting hosted virtual machines with unpartitioned disks, you might not be able to obtain hardware information about the source When converting hosted virtual machines with unpartitioned disks, you might not

The Local Group Policy Editor opens.

Your safest bet is to restore the registry hives into ALL control sets so that you can be sure you get it in the right spot. After the conversion, the helper VM retains the statically configured IP because it is still running. If your source computer is a PIC computer that runs a PIC HAL, you must update the HAL in the destination virtual machine to APIC HAL after the conversion. Vmware Converter Permission To Perform This Operation Was Denied He demonstrates how to download the file using a vSphere web client (or vSphere client) and exp… VMware Installing VMware vSphere ESXi 5.1 Video by: Peter This Micro Tutorial walks you

Reference documentation, the VMware vCenter Converter Standalone API Reference Guide, which provides language-neutral descriptive information (object type definitions, properties, and method signatures, for example) for the VMware vCenter Converter Standalone API Re: 98% FAILED: Unable to reconfigure the destination virtual machine. To find out which HAL is running, go to Windows Device Manager and select Computer in the list of devices. http://nbxcorp.com/vmware-converter/vmware-converter-error-unable-to-partition-the-destination-disks.html Top of Page Resolved Issues The Converter Standalone 5.5.1 release resolves the following issues: Converting Linux physical machines fails if the size of a destination disk is 2TB or larger If

Join the community Back I agree Powerful tools you need, all for free. It just assumes it will be at c:\windows and that c:\ will be partition(1). I knew it was too good to be true...BSOD with immediate reboot. C: disk was 70 GB and D: 205 GB.

By this time, its 1:30 AM and I really didn’t want to wait 90 minutes for the conversion to run again. Why was the server built that way??...nobody knows. Top of Page Linux Sources P2V conversions of SLES 9 sources cannot complete, if the root directory is located on an LVM disk Virtual machines cloned from SLES 11 SP1 sources Follow the article to export the registry sub-hives to .reg files from another windows 2003 virtual machine.

The person for whom I was doing this P2V could not test it, so I could not wrap up this thread.