How To Repair Winsock 10060 Error Tutorial


Home > Winsock Error > Winsock 10060 Error

Winsock 10060 Error

Contents

Please contact the server's administrator if this problem persists. WSAENOPROTOOPT 10042 Bad protocol option. Why can't the second fundamental theorem of calculus be proved in just two lines? An attempt was made to access a socket in a way forbidden by its access permissions. http://nbxcorp.com/winsock-error/winsock-error-code-10060-win32-error-code-10060-exchange-2013.html

more stack exchange communities company blog Stack Exchange Inbox Reputation and Badges sign up log in tour help Tour Start here for a quick overview of the site Help Center Detailed The remote host actively refused the attempt to connect to it. What would be the value of gold and jewelry in a post-apocalyptic society? Check that no old Windows Sockets DLL files are being accessed. http://support.dameware.com/kb/article.aspx?ID=300060

Winsock Error 10060 Exchange 2013

share|improve this answer edited Feb 10 '13 at 1:22 answered Feb 9 '13 at 23:58 Ansgar Wiechers 87.7k1166105 Yes,Its working now I set the port 25.............:) –vikky Feb 11 WSAEADDRINUSE (10048) Address already in use Only one usage of each address is normally permitted. Note that the v1.1 Winsock specification does not explicitly state that this error occurs if the value you request is larger than the WSAData.iMaxUdpDg returned from WSAStartup. Assuming you have a name server configured instead of or as well as a host table, a hostname resolution request causes a Winsock DLL to send a DNS 'A' record query

WSA_IO_INCOMPLETE 996 Overlapped I/O event object not in signaled state. Windows Firewall for SP2 or Vista, etc..) are properly configured to allow the necessary traffic to pass through. WSAEDISCON 10101 Graceful shutdown in progress. Error Code 10060 Socket Connection Failed This would have to be done either on the remote machine itself, or on the remote machine's defined Gateway. (see attached diagram) Lastly, if nothing else above resolves your issues, you

An error with the underlying traffic control (TC) API as the generic QoS request was converted for local enforcement by the TC API. Winsock Error 10060 Mdaemon However, you may also want to make sure all these remote machines are running the most current Video Drivers, NIC Drivers, etc... An invalid shaping rate object was found in the QoS provider-specific buffer. http://community.microfocus.com/borland/test/silk_performer_-_application_performance_testing/w/knowledge_base/9832.troubleshooting-errors-such-as-winsock-10060-connection-timeout.aspx You could not make a connection because the target computer actively refused it.

A socket already has a type (a protocol), and each sockaddr structure has an address family field to define its format. Winsock Error 10060 The Connection Timed Out Cannot translate a name. But we also suggest you try tweaking some of the performance settings mentioned above (Compression, Scan Blocks, etc...) to help with performance as well. This error is returned from operations on nonblocking sockets that cannot be completed immediately, for example recv when no data is queued to be read from the socket.

  • WSASYSCALLFAILURE 10107 System call failure.
  • A connect request was made on an already-connected socket.
  • WSAVERNOTSUPPORTED (10092) WINSOCK DLL Version out of range The current Winsock implementation does not support the Windows Sockets specification version requested by the application.
  • An application attempts to use an event object, but the specified handle is not valid.
  • This means another type of request to the name server will result in an answer.
  • Copyright © 1996-2011 GlobalSCAPE, Inc.
  • WSAECONNREFUSED (10061) Connection refused Connection refused: No connection could be made because the target machine actively refused it.
  • Typically, though, Winsock generates WSAENETUNREACH when it receives a 'host unreachable' ICMP message from a router instead of WSAEHOSTUNREACH.
  • WSAEREFUSED 10112 Database query was refused.
  • It's used for POP3 over SSL (i.e.

Winsock Error 10060 Mdaemon

This usually results from trying to connect to a service that is inactive on the foreign host—that is, one with no server application running. The specified socket parameter refers to a file, not a socket.WSAEDESTADDRREQ (10039) Destination address required A required address was omitted from an operation on a socket. Winsock Error 10060 Exchange 2013 WSA_NOT_ENOUGH_MEMORY 8 Insufficient memory available. Winsock Error 10061 WSAStartup may fail with this error if the limit has been reached.

A system call that should never fail has failed. Check This Out An invalid QoS provider-specific buffer. A request to send or receive data was disallowed because the socket is not connected and (when sending on a datagram socket using sendto) no address was supplied. WSAETIMEDOUT (10060) 10060 is a connection-timeout error that usually appears when the client does not receive a response from the server for a specific command. How To Fix Error Code 10060

Note that this error is returned by the operating system, so the error number may change in future releases of Windows. Either the application has not called WSAStartup or WSAStartup failed. A call to the WSALookupServiceEnd function was made while this call was still processing. Source Once the Mirror Driver has been installed on the remote machine, simply enable the "Use MRC Mirror Driver (if available)" checkbox on the Remote Connect dialog before you click on Connect.

If so, is there an older DLL in a directory in the path ahead of the directory containing the newer DLL? 10060 Socket Error There's at least one WinSock implementation that will occasionally fail a function and report this as the error value, even though the function succeeded. For example, you cannot use the ARPA Internet UDP protocol with type SOCK_STREAM.

A retry at some time later may be successful.

The FormatMessage function can be used to obtain the message string for the returned error. WSAEMSGSIZE (10040) Message too long A message sent on a socket was larger than the internal message buffer or some other network limit. Not the answer you're looking for? Socket Error 10060 Connection Timed Out Windows 7 You could also try to resolve another hostname you know should work, to check that the name resolution server application is running.

The following list describes the possible error codes returned by the WSAGetLastError function. Possible reasons: Wrong version of perfdotnetfw.dll, unhandled exception in constructor or insufficient permissions!". "DotNetCallMethod(DOTNET: 15 - Exception has been logged!, Only one element allowed per config file and if present For server applications that need to bind multiple sockets to the same port number, consider using setsockopt (SO_REUSEADDR). have a peek here Verify that the destination server name or IP address is correct Verify that the connection port number is correct (under Site Settings > Type tab).

It's also possible that the local services file has an incorrect port number (although it's unlikely). Note that this error is returned by the operating system, so the error number may change in future releases of Windows. If you continue to receive the same error after insuring ports 20 and 21 are open, contact the administrator of the site you are trying to connect to. By calling shutdown, you do a partial close of a socket, which means you have discontinued sending.

Try reconnecting at a later time.WSAECONNABORTED (10053) Software caused connection abort A connection abort was caused internal to your host machine. Client applications usually need not call bind at all—connect chooses an unused port automatically. For example, the error can occur when an attempt is made to read from a file that is not open, to open an existing read-only file for writing, or to open The requested service provider could not be loaded or initialized.

A socket operation encountered a dead host. WSAEDESTADDRREQ 10039 Destination address required. No more results can be returned by the WSALookupServiceNext function. back to top Socket Errors 10060, 10061, 10064, 10065 A socket error in the 10060 range is a Winsock error.

Check that the WINSOCK.DLL file is from the same vendor as your underlying protocol stack. Then click on RequestTimeoutSecs. WSA_INVALID_PARAMETER 87 One or more parameters are invalid. The ICMP message means that a router cannot forward the IP datagram, possibly because it did not get a response to an ARP request (which might mean the destination host is

Step 4.