However, there's little distinction between WSAEALREADY and WSAEINVAL since a WinSock DLL cannot tell the difference between an asynchronous operation that has been cancelled and one that was never valid. User suggestions: It may indicate that there are too many WinSock applications running simultaneously, but this is unlikely since most network systems have many socket handles available. The missing functions are getprotobyname(), getprotobynumber(), getservbyname(), and getservbyport(). Alternately, you could call getprotobyname() or WSAAsyncGetProtoByName() to get the appropriate protocol value from the network system. have a peek at this web-site

WSAENETRESET (10052) Net dropped connection or reset El host al cual estabas conectado se ha caido y reiniciado. An error with the underlying traffic control (TC) API as the generic QoS request was converted for local enforcement by the TC API. These errors might be reported on any function that does network I/O (e.g. We suggest local configuration changes that might remedy the problem, and network and server conditions that might be the cause. http://www.sockets.com/err_lst1.htm

Mdaemon Winsock Error 10054

In Berkeley, this error also occurs when you are trying to name the local socket (assign local address and port number) with bind(), but Windows Sockets doesn't ascribe this error to Detailed description: recv() and recvfrom(): if the datagram you read is larger than the buffer you supplied, then WinSock truncates the datagram (i.e. link errors in winsock 12. Developer suggestions: Things an application developer can do to avoid the error.

Developer suggestions: You need to be prepared to handle this error on any functions that reference blocking sockets, or any calls to blocking functions, if you allow the user to cancel WSAEADDRINUSE (10048) Address already in use. try to ping the server(s)). Winsock Error 10061 For example, you cannot use the ARPA Internet UDP protocol with type SOCK_STREAM.

Berkeley description: An operation that takes a long time to complete (such as a connect()) was attempted on a non-blocking socket. (see ioctl()). Winsock Error Windows 7 Try the following: Check that the WINSOCK.DLL file is in the current path. WSA_QOS_REQUEST_CONFIRMED 11009 QoS request confirmed. http://www.elbiah.de/hamster/doc/ref/errwinsock.htm But most of these function-less errors are simply out of place; they are inappropriate to the Windows Sockets API as it exists in the v1.1 specification.

WinSock description: Same as Berkeley. Winsock Error 10013 You should simply ignore this error when it occurs.WSAEINTR (10004) Interrupted system call A blocking operation was interrupted by a call to WSACancelBlockingCall. Subsequent operations fail with WSAECONNRESET. Note that this error is returned by the operating system, so the error number may change in future releases of Windows.

  • This error apparently also takes the place of WSAEPFNOSUPPORT (which means 'protocol family not supported'), since that error is not listed for socket.
  • WSAESHUTDOWN (10058) Can't send after socket shutdown Una peticion de envio de datos ha sido desactivada porque el socket estaba todavia desconexion con una llamada previa de desconexion.
  • The application has initiated an overlapped operation that cannot be completed immediately.
  • Note that the v1.1 Winsock specification does not explicitly state that this error occurs if the value you request is larger than the WSAData.iMaxUdpDg returned from WSAStartup.
  • Comprueba tu Winsock, pila del protocolo, driver de red y la configuracion de la interfaz de red.
  • These error codes and a short text description associated with an error code are defined in the Winerror.h header file.
  • User suggestions: Some network systems have commands to report statistics.
  • A call to the WSALookupServiceEnd function was made while this call was still processing.
  • Tambien puede indicar que no se han cerrado las aplicaciones correctamente.
  • If the signal handler performs a normal return, the interrupted function call will seem to have returned the error condition.

Winsock Error Windows 7

WSA_QOS_ADMISSION_FAILURE 11010 QoS admission error. look at this web-site The WinSock implementation will not allow you to send after this. Mdaemon Winsock Error 10054 The error occurs with the socket() function, which takes the socket type (protocol) and address family as input parameters. Winsock Error 0 WSAEINVALIDPROVIDER 10105 Service provider is invalid.

WSAEREMOTE 10071 Item is remote. Check This Out Whether to handle it as a fatal error or non-fatal error depends on the application and the context, so it's entirely up to you to decide. If so, is there an older DLL in a directory in the path ahead of the directory containing the newer DLL? WinSock description: Same as Berkeley. Wsaeconnaborted 10053

Usually this occurs when a file descriptor refers to a file or socket that cannot support this operation, for example, trying to accept a connection on a datagram socket. If you are using a name server(s), check whether the server host(s) are up (e.g. An object with an invalid ObjectLength field was specified in the QoS provider-specific buffer. Source WSAENOMORE 10102 - (Winsock2) WSAECANCELLED 10103 - (Winsock2) WSAEINVALIDPROCTABLE 10104 - (Winsock2) WSAEINVALIDPROVIDER 10105 - (Winsock2) WSAEPROVIDERFAILEDINIT 10106 - (Winsock2) WSASYSCALLFAILURE 10107 System call failure. (WS2) WSASERVICE_NOT_FOUND 10108 - (Winsock2) WSATYPE_NOT_FOUND

WinSock description: Similar to Berkeley. Winsock Error 10060 WSAECONNRESET 10054 Connection reset by peer. An operation was attempted on something that is not a socket.

The "address" it refers to is the remote socket name (protocol, port and address).

It is a nonfatal error, and the operation should be retried later. WinSock - Handle Invalid Certificate Authority Error Hi I can't ignore "The sertificate authority is invalid or incorrect" error, even if I set SECURITY_FLAG_IGNORE_UNKNOWN_CA flag. Once we are happy that Winsock has initialized correctly, we can now use a handy function to address any further failures. Wsaenotsock WSA_QOS_BAD_OBJECT 11013 QoS bad object.

WinSock description: No equivalent. Berkeley description: A directory with entries other than `.'and `..' was supplied to a remove directory or rename call. Networking activity on the local host has not been initiated. have a peek here For protocol and services resolution, the name or number was not found in the respective database.

WSAEUSERS 10068 Too many users. Don't believe me? The v1.1 WinSock specification only ascribes thirty-three of the fifty errors to any of the WinSock functions in the v1.1 for Windows Sockets specification. Note that the v1.1 WinSock specification does not explicitly state that this error occurs if the value you request is larger than the WSAData.iMaxUdpDg returned from WSAStartup().

In other words, the Winsock you are using is not supported by the program you are using. User suggestions: Check the obvious first: check that the destination address is a valid IP address. WSA_QOS_NO_SENDERS 11007 No QoS senders. No more results can be returned by the WSALookupServiceNext function.

A socket already has a type (a protocol), and each sockaddr structure has an address family field to define its format. Now we examine error handling in greater detail. This may be because the database files (for example, BSD-compatible HOSTS, SERVICES, or PROTOCOLS files) could not be found, or a DNS request was returned by the server with a severe This is not a software error, another type of name server request may be successful.